- Trang chủ
- Sensor & Transmitter
- CD-P series duct mount transmitters
CD-P series duct mount transmitters
Hàng hot: | Lượt xem: 1658
Danh mục : Sensor & Transmitter
Nhãn hiệu : Johnson Controls
The CD-P series duct mount transmitters are designed for the measurement of Carbon Dioxide (CO2) and Temperature in Heating Ventilating and Air Conditioning applications where Demand Control Ventilation (DCV), fresh air and indoor Air Quality (IAQ), and rooftop air handling economizer control systems are often required.
Mã | Mô tả | Giá thành viên | Mua hàng |
---|---|---|---|
CD-P1000-00-00 | CO2 DUCT 2000PPM (Duct CO2 0/2000 PPM, output 0..10 V or 4..20 mA field selectable) | Đăng nhập | Đăng nhập |
CD-P2010-00-00 | CO2 DUCT - ACT T. 0/50C (Duct CO2 0/2000 PPM, output 0..10 V or 4..20 mA selectable + Temperature 0 .. 10 V @ 0..50 °C) | Đăng nhập | Đăng nhập |
CD-P2016-00-00 | CO2 DUCT - PT1000 (Duct CO2 0/2000 PPM, output 0..10 V or 4..20 mA selectable + passive Pt1000) | Đăng nhập | Đăng nhập |
CD-P2017-00-00 | CO2 DUCT - NTC10K (Duct CO2 0/2000 PPM, output 0..10 V or 4..20 mA selectable + passive NTC10K ) | Đăng nhập | Đăng nhập |
Features
The Johnson Controls® CD-Px0xx-00-00 Series duct mount transmitters are designed for the measurement of CO2 and temperature in HVAC applications where demand control ventilation (DCV), fresh air and indoor Air Quality (IAQ), and rooftop air handling economizer control systems are often required.
The CD-P Series sensors incorporate a dual wavelength non-dispersive infrared (NDIR) CO2 sensor, which compensates for aging effects, is highly insensitive to pollution, and offers outstanding long-term stability
The CD-P1000-00-00 transmitter is available with CO2output only,0 to 10 V or 4 to 20 mA while the CD-P2000 Series offers CO2and temperature measurement with active or passive outputs.
A multiple point CO2factory adjustment procedure leads to excellent CO2measurement accuracy over the entire temperature working range.
Features and Benefits
Adjustable duct probe depth—Permits optimal placement of sensing tip in a duct
Support for DCV—Offers potential for 10 to 70% energy savings.
Single-beam dual-wavelength NDIR CO2sensor—Is highly insensitive to pollution with outstanding long-term stability
Models include CO2 and CO2+ temperature outputs—Reduces installation time and cost
0 to 10 V or passive temperature output—Is suitable for a wider range of applications
Factory calibration certificate—Includes test report according to DIN EN10204 - 2.2.