TE-6313P-1 Temperature Sensor

Lượt xem: 660

Danh mục : Sensor & Transmitter
Nhãn hiệu : Johnson Controls
Dòng sản phẩm : TE-6300 Series Temperature Sensor
*Đây là hình đại diện cho dòng sản phẩm này và có thể sai khác với sản phẩm thực tế.

TEMP SENSOR; 1000 OHM NI (Outdoor Temperature sensor, -46 to 50°C, Ni1000)

Mô tả Giá thành viên Mua hàng
TE-6313P-1 TEMP SENSOR; 1000 OHM NI (Outdoor Temperature sensor, -46 to 50°C, Ni1000) Đăng nhập Đăng nhập

Description

The TE-6300 Temperature Sensor line provides economical solutions for a wide variety of temperature sensing needs, including wall-mount, outdoor-air, duct, strap-mount, well-insertion, duct-averaging, and VAV Modular Assembly (VMA) flange-mount duct-probe applications. The TE-6300 line offers both a metal and a plastic enclosure for the most popular models.

Sensors are available in the following types:

1k ohm thin-film nickel

1k ohm nickel averaging

1k ohm thin-film platinum

100 ohm platinum equivalent averaging

1k ohm platinum equivalent averaging

2.2k (2,252) ohm thermistor

10k ohm thermistor, Johnson Controls® Type II

Features and Benefits

Each sensor is packaged with the necessary mounting accessories to maximize ordering and installation ease and to reduce both commissioning time and cost.

Full Line of Versatile Sensors—Supports all your temperature sensing needs from a single supplier: wall-mount, outdoor-air, duct, duct-averaging, strap-mount, well-insertion, and flange-mount duct-probe.

Single Assembly Ordering—Simplifies ordering; provides a complete assembly in one box.

Models Featuring an Integral National Pipe Thread (NPT) Adaptor—Increase sensor connection strength, which eliminates the need for a special adaptor

Metal Enclosure (TE-63xxE, TE-63xxM, and TE-63xxV Models)—Meets plenum requirements.

Models Featuring a Retainer for the Sensor Holder—Allow you to lock the sensor holder into the conduit box.

Brushed Stainless Steel Mounting Plate—Offers a durable, aesthetically pleasing design.

Low Profile Flush Mount Design (TE-63xxF Models)—Provides a tamper-proof installation ideally suited for schools, sporting complexes, retailers, prisons, and more.

All TE-6300 Series Temperature Sensors are two-wire, passive, resistance-output devices


TE-63xxA Models

The TE-63xxA (adjustable length) models:

provide a thermoplastic mounting flange and gland nut to adjust the length of the probe

include two hex-head self-drilling screws for mounting

come equipped with a 10 ft (3 m) plenum-rated cable with 1/4 in. (6.35 mm) internal thread insulated quick-connect terminations on leads

TE-63xxE Models

The TE-63xxE (economizer mount) models

provide a stainless steel mounting flange

include two hex-head self-drilling screws for mounting

meet UL 1995 plenum use requirements

TE-63xxF Models

The TE-63xxF (flush mount) models:

provide a low profile when installed in an electrical box

thermally isolate sensor from the wall with a foam pad

offer a rugged stainless steel cover

provide 22 AWG (0.6 mm diameter) lead wires with low voltage installation

TE-63xxM Models

The TE-63xxM (metal enclosure) models

come with a corrosion-protected steel enclosure with a 0.88 in. (22 mm) hole for a 1/2 in. (12.7 mm) conduit fitting

include two hex-head self-drilling screws for mounting the duct and duct-averaging models

offer either a direct-mount or 1/2-14 NPT threaded well sensor holder for mounting in TE-6300W Series Thermowells (well models; order the thermowell separately)

provide optional well sensor holders (order separately) to mount duct models in thermowells

meet UL 1995 plenum use requirements

offer optional accessory kit (order separately) to replace plastic hole plug and wiring bushing to meet International Mechanical Code (IMC) requirements

TE-63xxP Models

The TE-63xxP (plastic enclosure) models:

provide a thermoplastic conduit box with 1/2-14 internal NPT for connecting to conduit

provide aluminum mounting plate and 1/2-14 internal NPT hub mounting options for the duct and duct-averaging models

use the 1/2-14 internal NPT to mount the outdoor air models directly to rigid conduit

include sensor holders to mount duct models in thermowells (order thermowell separately)

offer an optional accessory metal cover and gasket kit (order separately) to replace the plastic cover to meet UL 1995 plenum use requirements

include a replaceable sensing probe on duct-probe, outdoor-air, and well-insertion models

TE-63x4P Wall Mount Models

The TE-63x4P (plastic enclosure) models:

come with a white thermoplastic ventilated cover with a brushed aluminum face plate and a steel mounting plate for surface mounting

include faceplates for both horizontal and vertical mounting

offer an accessory mounting kit for mounting to a standard electrical box

offer optional covers

TE-63xS Models

The TE-63xS (strap-mount) models:x

provide a 1/4 in. (6.35 mm) diameter stainless steel probe without an enclosure

include three cable ties for mounting to pipe up to 2-5/8 in. (67 mm) in diameter

come equipped with a 10 ft (3 m) plenum-rated cable

meet UL 1995 plenum use requirements

offer an accessory mounting kit for mounting to a pipe up to 11 in. (280 mm) in diameter

TE-63xxV Models

The TE-63xxV (VAV flange mount) models

provide a stainless steel mounting flange with two hex-head self-drilling mounting screws

come equipped with a 10 ft (3 m) plenum-rated cable with 1/4 in. (6.35 mm) internal thread insulated quick-connect terminations on leads

meet UL 1995 plenum use requirements

1 TE-6300 Series Temperature Sensors Catalog Page
2 TE-6300 Series Temperature Sensors Product Bulletin